Fire Alarm Siren
Color: Red
Power Source: Battery Powered
Product Dimensions: 4.53″L x 1.89″W x 5.31″H
Voltage: 24 Volts

عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
منتجات ذات صلة
Conventional Fire Panels
- EN 54-2 and EN 54-4 certified.
- Conventional fire panel.
- Compatible with all manufactured conventional detectors.
- Fire lines 2, 4, 6 or 8.
- Outputs – 12, 16 or 20 relay-type embedded.
- Control lines and monitoring outputs for fault conditions (short circuit and interruption) and automatic reset.
- Light and textual indication for Fire condition, Fault, Prohibition and Test.
- Ability to delay controllable outputs and general fire for a period of 10 to 600 seconds after the state registration of fire.
- Built-in sounder for fire – one tonal, continuous with the possibility of exclusion; Status Test each fire alarm lines.
Customized logo
Fire Extinguishing Control Panel
Inputs Specifications:
- L1 and L2– Conventional
- Zones for extinguishing
- L3 Conventional Zone for Fire Alarm
- Low Press. input – supervised balanced input
- Manual release input – supervised balanced inputOutputs Specifications:
- S 1 (Sounder 1) – Monitored, 24V DC, 500mA
- S 2 (Sounder 2) – Monitored, 24V DC, 500mA
- Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
- Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
- Fault relay(NC, COM, NO), 5-30V DC/1A
Manual Call Point
- Supply voltage: (9-30) V / DC
- Resistance: 500Ω / (1 kΩ in broken PCB bridge)
- Current at 24V, 46mA / (22mAin broken PCB bridge)
- LED indicator: Red
- Protective cover: transparent
- Cross section of connecting cables: 0,4÷1,5 mm2
- Operating temperature range: minus 10ºС ÷ 50ºС
- Humidity: (93 ± 3)% at40ºС
- Degree of protection: IP 40
- Dimensions: (90 х 90 х 44) mm
- Weight: 0,120 kg
- Material: ABS plastic
Power Supply Panel
- Plastic box;
- Input voltage (187-253)V AC, 50Hz.
- Output voltage (18-27.6)V/DC.
- Output current (in the presence of main power supply) – up to 2.0A (continuous).
- Output current (in absence of mains power supply and fully charged back-up battery) – 3.5A up to 1h.
- Back-up battery – 2x12V / 5Ah.
- 5 Led indicators.
- Developed under the requirements of EN 54-4.
Rate of rise heat detector
- - Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g
Remote Indicator
The remote indicator is designed to duplicate the fire alarm signal from a fire detector as well as to duplicate indications from executive devices and signaling.
- Supply voltage: 9-28 V DC
- Current in alarm: 40 mA / 24V DC
- Indicator color: Red
- Type of connecting line: Two-wire
- Sequential resistor: 560Ω / 0.6W
- Dimensions: (75x75x22) mm
- Mass: 0.04 kg
المراجعات