Conventional Optical Smoke Detector

100 

Features:

  • Conventional Optical smoke detector;
  • Certified: EN 54-7;
  • Supply voltage: (10-30) V/DC
  • Power consumption in Duty condition: ≤ 130 µА
  • Consumption in “Fire” condition: 20 mА/ 24V DC
  • Operating temperature range: minus 10°С ÷ plus 50°С;
  • Protected area: Circle with diameter 15m, h 11m.

Conventional Rate of rise heat detector

100 

Features:

- Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g

Dual Element Infrared Detector

90 

Features:

  • Installation height – 2.2m
  • Directional pattern : 1 4 x 1 4 m,. 90 degrees

Specifications:

Operating voltage: 9-16VDC ● Current draw: 17mA ● Alarm interval: 1 second ● Pulses: 1, 2 or 3 jumper selectable ● Sensor: dual element infrared

Fire Alarm Siren

120 

Features:

Color: Red

Power Source: Battery Powered

Product Dimensions: 4.53"L x 1.89"W x 5.31"H

Voltage: 24 Volts

Fire Extinguishing Control Panel

1.000 

Specifications:

  • L1 and L2– Conventional
  • Zones for extinguishing
  • L3 Conventional Zone for Fire Alarm
  • Low Press. input – supervised balanced input
  • Manual release input – supervised balanced input

Outputs Specifications:

    • S 1 (Sounder 1) – Monitored, 24V DC, 500mA
    • S 2 (Sounder 2) – Monitored, 24V DC, 500mA
    • Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
    • Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
    • Fault relay(NC, COM, NO), 5-30V DC/1A

Manual Release – Yellow

100 

Features:

The button operates with extinguishing control panel and activates the extinguishing. It is to be installed close to the object of extinguishing. By means of this button forced extinguishing process can be started only after visual inspection of an authorized person if a there is a real fire condition. Fire alarm line is controlled for a short circuit and for an interruption.

Power Supply Panel

350 

Features:

  • Plastic box;
  • Input voltage (187-253)V AC, 50Hz.
  • Output voltage (18-27.6)V/DC.
  • Output current (in the presence of main power supply) – up to 2.0A (continuous).
  • Output current (in absence of mains power supply and fully charged back-up battery) – 3.5A up to 1h.
  • Back-up battery – 2x12V / 5Ah.
  • 5 Led indicators.
  • Developed under the requirements of EN 54-4.

Remote Indicator

25 

Features:

The remote indicator is designed to duplicate the fire alarm signal from a fire detector as well as to duplicate indications from executive devices and signaling.

  • Supply voltage: 9-28 V DC
  • Current in alarm: 40 mA / 24V DC
  • Indicator color: Red
  • Type of connecting line: Two-wire
  • Sequential resistor: 560Ω / 0.6W
  • Dimensions: (75x75x22) mm
  • Mass: 0.04 kg

Security System

1.200 

FORCE 32C is an alarm system designed for private houses and small businesses. It has 8 onboard zones and can expand to up to 32 zones.

The system supports multipath communication options including Ethernet, PSTN, cellular and long-range radio.

Features:

  • 8 security zones expandable to 32 zones
  • 24 wireless zones
  • Up to 32 users
  • Up to 16 contacts
  • Up to 4 partitions
  • Up to 8 keypads
  • 4 partial arming modes
  • Report to 3 CMS
  • Remote firmware upgrade

Weatherproof 24VDC Horn Strobe, Wall Mount

350 

Features:

Candela Horn/Strobe 5.75" High x 4.75" Wide x 4.18" Deep Switch Selection for High dBA Switch for Mechanical and 2400hz Tone Switch for Continuous Tone Input terminals supports 12 to 18 gauge wire Tamperproof Re-entrant Grill Wide Voltage Range of 16-33 VDC or FWR Separate Horn and Strobe Functions