Features:
addressable heat maximum-differential rate of rise fire detector, for addressable systems supporting DM Tech communication protocol. |

عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
منتجات ذات صلة
Addressable Module with 1 Output and 1 Input
Conventional Fire Panels
Features:
- EN 54-2 and EN 54-4 certified.
- Conventional fire panel.
- Compatible with all manufactured conventional detectors.
- Fire lines 2, 4, 6 or 8.
- Outputs – 12, 16 or 20 relay-type embedded.
- Control lines and monitoring outputs for fault conditions (short circuit and interruption) and automatic reset.
- Light and textual indication for Fire condition, Fault, Prohibition and Test.
- Ability to delay controllable outputs and general fire for a period of 10 to 600 seconds after the state registration of fire.
- Built-in sounder for fire – one tonal, continuous with the possibility of exclusion; Status Test each fire alarm lines.
Manual Release – Yellow
Features:
The button operates with extinguishing control panel and activates the extinguishing. It is to be installed close to the object of extinguishing. By means of this button forced extinguishing process can be started only after visual inspection of an authorized person if a there is a real fire condition. Fire alarm line is controlled for a short circuit and for an interruption.
Rate of rise heat detector
Features:
- Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g
Remote Indicator
Features:
The remote indicator is designed to duplicate the fire alarm signal from a fire detector as well as to duplicate indications from executive devices and signaling.
- Supply voltage: 9-28 V DC
- Current in alarm: 40 mA / 24V DC
- Indicator color: Red
- Type of connecting line: Two-wire
- Sequential resistor: 560Ω / 0.6W
- Dimensions: (75x75x22) mm
- Mass: 0.04 kg
Strobe Sounder Beacon
Weatherproof 24VDC Horn Strobe, Wall Mount
Features:
Candela Horn/Strobe 5.75" High x 4.75" Wide x 4.18" Deep Switch Selection for High dBA Switch for Mechanical and 2400hz Tone Switch for Continuous Tone Input terminals supports 12 to 18 gauge wire Tamperproof Re-entrant Grill Wide Voltage Range of 16-33 VDC or FWR Separate Horn and Strobe Functions