Dual Element Infrared Detector
$1.00
Features:
- Installation height – 2.2m
- Directional pattern : 1 4 x 1 4 m,. 90 degrees
Specifications:
Operating voltage: 9-16VDC
● Current draw: 17mA
● Alarm interval: 1 second
● Pulses: 1, 2 or 3 jumper selectable
● Sensor: dual element infrared

عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
منتجات ذات صلة
Addressable heat fire detector
Ceiling Mount Quad Detector
Conventional Fire Strobe Sounder
Features:
The AW-CSS2166-4 is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
In the event of a fire can be an effective warning sound and flash to notify people to evacuate.
Fire Extinguishing Control Panel
Specifications:
- L1 and L2– Conventional
- Zones for extinguishing
- L3 Conventional Zone for Fire Alarm
- Low Press. input – supervised balanced input
- Manual release input – supervised balanced input
Outputs Specifications:
-
- S 1 (Sounder 1) – Monitored, 24V DC, 500mA
- S 2 (Sounder 2) – Monitored, 24V DC, 500mA
- Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
- Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
- Fault relay(NC, COM, NO), 5-30V DC/1A
Manual Release – Yellow
Features:
The button operates with extinguishing control panel and activates the extinguishing. It is to be installed close to the object of extinguishing. By means of this button forced extinguishing process can be started only after visual inspection of an authorized person if a there is a real fire condition. Fire alarm line is controlled for a short circuit and for an interruption.
Rate of rise heat detector
Features:
- Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g
Remote Indicator
Features:
The remote indicator is designed to duplicate the fire alarm signal from a fire detector as well as to duplicate indications from executive devices and signaling.
- Supply voltage: 9-28 V DC
- Current in alarm: 40 mA / 24V DC
- Indicator color: Red
- Type of connecting line: Two-wire
- Sequential resistor: 560Ω / 0.6W
- Dimensions: (75x75x22) mm
- Mass: 0.04 kg
Weatherproof 24VDC Horn Strobe, Wall Mount
Features:
Candela Horn/Strobe 5.75" High x 4.75" Wide x 4.18" Deep Switch Selection for High dBA Switch for Mechanical and 2400hz Tone Switch for Continuous Tone Input terminals supports 12 to 18 gauge wire Tamperproof Re-entrant Grill Wide Voltage Range of 16-33 VDC or FWR Separate Horn and Strobe Functions