Fire Extinguishing Control Panel
Inputs Specifications:
- L1 and L2– Conventional
- Zones for extinguishing
- L3 Conventional Zone for Fire Alarm
- Low Press. input – supervised balanced input
- Manual release input – supervised balanced inputOutputs Specifications:
- S 1 (Sounder 1) – Monitored, 24V DC, 500mA
- S 2 (Sounder 2) – Monitored, 24V DC, 500mA
- Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
- Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
- Fault relay(NC, COM, NO), 5-30V DC/1A

عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
منتجات ذات صلة
Addressable Optical smoke detector
Ceiling Mount Quad Detector
Conventional Fire Panels
- EN 54-2 and EN 54-4 certified.
- Conventional fire panel.
- Compatible with all manufactured conventional detectors.
- Fire lines 2, 4, 6 or 8.
- Outputs – 12, 16 or 20 relay-type embedded.
- Control lines and monitoring outputs for fault conditions (short circuit and interruption) and automatic reset.
- Light and textual indication for Fire condition, Fault, Prohibition and Test.
- Ability to delay controllable outputs and general fire for a period of 10 to 600 seconds after the state registration of fire.
- Built-in sounder for fire – one tonal, continuous with the possibility of exclusion; Status Test each fire alarm lines.
Conventional Fire Strobe Sounder
The AW-CSS2166-4 is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire. By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue. In the event of a fire can be an effective warning sound and flash to notify people to evacuate.