Ceiling Mount Quad Detector
Companion Microphone Stand
Conventional Fire Panels
Features:
- EN 54-2 and EN 54-4 certified.
- Conventional fire panel.
- Compatible with all manufactured conventional detectors.
- Fire lines 2, 4, 6 or 8.
- Outputs – 12, 16 or 20 relay-type embedded.
- Control lines and monitoring outputs for fault conditions (short circuit and interruption) and automatic reset.
- Light and textual indication for Fire condition, Fault, Prohibition and Test.
- Ability to delay controllable outputs and general fire for a period of 10 to 600 seconds after the state registration of fire.
- Built-in sounder for fire – one tonal, continuous with the possibility of exclusion; Status Test each fire alarm lines.
- The Price Just for 2 Zones !.
Conventional Fire Strobe Sounder
Features:
The AW-CSS2166-4 is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.
By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.
In the event of a fire can be an effective warning sound and flash to notify people to evacuate.
Conventional Manual Call Point
Features:
- Supply voltage: (9-30) V / DC
- Resistance: 500Ω / (1 kΩ in broken PCB bridge)
- Current at 24V, 46mA / (22mAin broken PCB bridge)
- LED indicator: Red
- Protective cover: transparent
- Cross section of connecting cables: 0,4÷1,5 mm2
- Operating temperature range: minus 10ºС ÷ 50ºС
- Humidity: (93 ± 3)% at40ºС
- Degree of protection: IP 40
- Dimensions: (90 х 90 х 44) mm
- Weight: 0,120 kg
- Material: ABS plastic
Conventional Optical Smoke Detector
Conventional Rate of rise heat detector
Features:
- Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g
Double Doors Recognition Access Control Controller
Dual Element Infrared Detector
Face Recognition Access Control
:Features
- Ultra-fast & accurate face recognition — over 99% accuracy, under 1% false rate, with recognition in just 0.2 seconds using onboard deep-learning hardware.
- Supports multiple authentication methods — face, Mifare card, and password/PIN.
- Large storage capacity — holds up to 10,000 faces and 10,000 cards; logs up to 30,000 events with images, and 100,000 without images
- Flexible integration — interfaces include LAN (RJ45), RS‑485, Wiegand in/out, door lock, alarm in/out, exit button, and door contact support
- Compact and practical design — 4" touch screen (480 × 800 resolution), LED + IR lighting, robust all-weather performance (–20 °C to +60 °C, RH <95%), weighs around 242 g
Fire Alarm Siren
Fire Extinguishing Control Panel
Specifications:
- L1 and L2– Conventional
- Zones for extinguishing
- L3 Conventional Zone for Fire Alarm
- Low Press. input – supervised balanced input
- Manual release input – supervised balanced input
Outputs Specifications:
-
- S 1 (Sounder 1) – Monitored, 24V DC, 500mA
- S 2 (Sounder 2) – Monitored, 24V DC, 500mA
- Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
- Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
- Fault relay(NC, COM, NO), 5-30V DC/1A