عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام

Addressable fire control panel

2.200 

Features:

an addressable fire control panel with 1 loop and supports 250 address devices in a loop.

Addressable heat fire detector

170 

Features:

 addressable heat maximum-differential rate of rise fire detector, for addressable systems supporting DM Tech communication protocol.

Addressable Manual Call Point Detector

170 

Features:

  • Addressable Manual Call Point Detector.
  • Certified EN 54-11 and EN 54-17.
  • Power consumption in Duty condition: ≤ 500 µА.
  • Consumption in “Fire” condition: 2 mА.

Addressable Module for Conventional Zone

300 

Features:

  • Addressable Module for Conventional Zone;.
  • Certified EN 54-18 and EN 54-17.
  • Power consumption in Duty condition: ≤ 500μА.
  • Consumption in Alarm mode:  2,5 mА.

Addressable Module with 1 Output and 1 Input

300 

Features:

  • Addressable Module with 1 Output and 1 Input.
  • Certified EN 54-18 and EN 54-17.
  • Power consumption in Duty condition: ≤ 500 µА.
  • Consumption in Alarm mode: 6 mА.

Addressable Optical smoke detector

170 

Features:

  • Addressable Optical smoke detector.
  • Certified: EN 54-7 and EN 54-17.
  • Power consumption in Duty condition: ≤ 500 µА.
  • Consumption in “Fire” condition: 2 mА.

Conventional Fire Panels

850 

Features:

  • EN 54-2 and EN 54-4 certified.
  • Conventional fire panel.
  • Compatible with all manufactured conventional detectors.
  • Fire lines 2, 4, 6 or 8.
  • Outputs – 12, 16 or 20 relay-type embedded.
  • Control lines and monitoring outputs for fault conditions (short circuit and interruption) and automatic reset.
  • Light and textual indication for Fire condition, Fault, Prohibition and Test.
  • Ability to delay controllable outputs and general fire for a period of 10 to 600 seconds after the state registration of fire.
  • Built-in sounder for fire – one tonal, continuous with the possibility of exclusion; Status Test each fire alarm lines.
  • The Price Just for 2 Zones !.

Conventional Fire Strobe Sounder

250 

Features:

The AW-CSS2166-4 is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire.

By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue.

In the event of a fire can be an effective warning sound and flash to notify people to evacuate.

Conventional Optical Smoke Detector

100 

Features:

  • Conventional Optical smoke detector;
  • Certified: EN 54-7;
  • Supply voltage: (10-30) V/DC
  • Power consumption in Duty condition: ≤ 130 µА
  • Consumption in “Fire” condition: 20 mА/ 24V DC
  • Operating temperature range: minus 10°С ÷ plus 50°С;
  • Protected area: Circle with diameter 15m, h 11m.

Conventional Rate of rise heat detector

100 

Features:

- Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g

Fire Extinguishing Control Panel

1.000 

Specifications:

  • L1 and L2– Conventional
  • Zones for extinguishing
  • L3 Conventional Zone for Fire Alarm
  • Low Press. input – supervised balanced input
  • Manual release input – supervised balanced input

Outputs Specifications:

    • S 1 (Sounder 1) – Monitored, 24V DC, 500mA
    • S 2 (Sounder 2) – Monitored, 24V DC, 500mA
    • Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
    • Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
    • Fault relay(NC, COM, NO), 5-30V DC/1A

Manual Call Point

100 

Features:

  • Supply voltage: (9-30) V / DC
  • Resistance: 500Ω / (1 kΩ in broken PCB bridge)
  • Current at 24V, 46mA / (22mAin broken PCB bridge)
  • LED indicator: Red
  • Protective cover: transparent
  • Cross section of connecting cables: 0,4÷1,5 mm2
  • Operating temperature range: minus 10ºС ÷ 50ºС
  • Humidity: (93 ± 3)% at40ºС
  • Degree of protection: IP 40
  • Dimensions: (90 х 90 х 44) mm
  • Weight: 0,120 kg
  • Material: ABS plastic