Manual Call Point
- Supply voltage: (9-30) V / DC
- Resistance: 500Ω / (1 kΩ in broken PCB bridge)
- Current at 24V, 46mA / (22mAin broken PCB bridge)
- LED indicator: Red
- Protective cover: transparent
- Cross section of connecting cables: 0,4÷1,5 mm2
- Operating temperature range: minus 10ºС ÷ 50ºС
- Humidity: (93 ± 3)% at40ºС
- Degree of protection: IP 40
- Dimensions: (90 х 90 х 44) mm
- Weight: 0,120 kg
- Material: ABS plastic

عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
منتجات ذات صلة
Addressable heat fire detector
Conventional Fire Panels
- EN 54-2 and EN 54-4 certified.
- Conventional fire panel.
- Compatible with all manufactured conventional detectors.
- Fire lines 2, 4, 6 or 8.
- Outputs – 12, 16 or 20 relay-type embedded.
- Control lines and monitoring outputs for fault conditions (short circuit and interruption) and automatic reset.
- Light and textual indication for Fire condition, Fault, Prohibition and Test.
- Ability to delay controllable outputs and general fire for a period of 10 to 600 seconds after the state registration of fire.
- Built-in sounder for fire – one tonal, continuous with the possibility of exclusion; Status Test each fire alarm lines.
Conventional Fire Strobe Sounder
The AW-CSS2166-4 is a conventional type sound and light alarm, sound and light for short. It is an automatic fire alarm system output devices, mainly through the alarm will sound and flash signal, suggesting that people fire. By DC 24V electrical signal to the conventional type of sound and light alarms powered, it sounds an alarm buzzer and flashing lights flash issue. In the event of a fire can be an effective warning sound and flash to notify people to evacuate.
iPhone dock
Optical Smoke Detector
Rate of rise heat detector
- - Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g
Security System
FORCE 32C is an alarm system designed for private houses and small businesses. It has 8 onboard zones and can expand to up to 32 zones.
The system supports multipath communication options including Ethernet, PSTN, cellular and long-range radio.
Features
- 8 security zones expandable to 32 zones
- 24 wireless zones
- Up to 32 users
- Up to 16 contacts
- Up to 4 partitions
- Up to 8 keypads
- 4 partial arming modes
- Report to 3 CMS
- Remote firmware upgrade
المراجعات
لا توجد مراجعات بعد.