Strobe Sounder Beacon
$1.00
Features:
AW-D316 Conventional Sounder Beacon can give audible and visual alarms after being connected to a DC24V power supply. It can be used with a bus-type fire alarm control panel through an output module. After receiving a start command given by the fire alarm

عرض الاصناف من خلال استخدام العلامة التجارية لكل صنف للمساعدة على فرز الاصناف مجمعة تحت اسم الشركة المصنعة مع اختلاف طبيعة الصنف وتنوع الاستخدام


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
منتجات ذات صلة
Addressable Module for Conventional Zone
Addressable Module with 1 Output and 1 Input
Ceiling Mount Quad Detector
Customized logo
Fire Extinguishing Control Panel
Specifications:
- L1 and L2– Conventional
- Zones for extinguishing
- L3 Conventional Zone for Fire Alarm
- Low Press. input – supervised balanced input
- Manual release input – supervised balanced input
Outputs Specifications:
-
- S 1 (Sounder 1) – Monitored, 24V DC, 500mA
- S 2 (Sounder 2) – Monitored, 24V DC, 500mA
- Rel 1ST Stage 1 relay “Fire Alarm” (NC, COM, NO), 5-30V DC/1A
- Rel 2ST Stage 2 relay “Extinguishing Activated” (NC, COM, NO), 5-30V DC/1A
- Fault relay(NC, COM, NO), 5-30V DC/1A
Manual Call Point
Features:
- Supply voltage: (9-30) V / DC
- Resistance: 500Ω / (1 kΩ in broken PCB bridge)
- Current at 24V, 46mA / (22mAin broken PCB bridge)
- LED indicator: Red
- Protective cover: transparent
- Cross section of connecting cables: 0,4÷1,5 mm2
- Operating temperature range: minus 10ºС ÷ 50ºС
- Humidity: (93 ± 3)% at40ºС
- Degree of protection: IP 40
- Dimensions: (90 х 90 х 44) mm
- Weight: 0,120 kg
- Material: ABS plastic
Rate of rise heat detector
Features:
- Supply voltage 10-30 V DC - Current consumption in Standby mode ≤ 130 µА - Current consumption in Alarm condition 20 mА/ 24V DC - Time to enter standby mode after reset up to 35s - Reset time 2s - Degree of protection IP 43 - Type of the connecting line to the base 0,5÷1,5 mm2/ two-wire - Output in Alarm condition (term. 3) limited to 2 kΩ, negative - Operating temperature range -10ºС up to 50ºС - Humidity (93 ± 3)% at 40ºС - Dimensions with base Ø 100mm h ≤ 52mm - Weight ≤ 100g